ADR Functionality User Manual ADR Functional Reference
Trigger on XY Vector or Z axis
An event is triggered when either:
The magnitude of the Z acceleration exceeds the Z Axis Event Trigger Level, or
The magnitude of the XY acceleration vector exceeds the XY Vector Event Trigger Level.
An event is considered as a severe event when either:
The magnitude of the Z acceleration exceeds the Z Axis Severe Event Trigger Level, or
The magnitude of the XY acceleration vector exceeds the XY Vector Severe Event Trigger Level.
The trigger filter setting used for the Z axis is separately configurable to the setting used for the X and Y axes.
Trigger on X or Y or Z axis
An event is triggered when either:
The magnitude of the Z acceleration exceeds the Z Axis Event Trigger Level, or
The magnitude of the X or Y acceleration exceeds the X and Y Axes Event Trigger Level.
An event is considered as a severe event when either:
The magnitude of the Z acceleration exceeds the Z Axis Severe Event Trigger Level, or
The magnitude of the X or Y acceleration exceeds the X and Y Axes Severe Event Trigger Level.
The trigger filter setting used for the Z axis is separately configurable to the setting used for the X and Y axes.
General Notes on Triggering:
The event trigger starts the event logging process. The log contains 2 seconds of pre-trigger data and 30 seconds
of post-trigger data.
The log files generated by ADR Manager contain the trigger filter output that was used to trigger the event. These
readings can be used to determine suitable filtering and thresholds.